2014年7月29日 星期二

H.C.B-A1541 DIGITAL CALIPER -Auto repair tools



Product Description :
2014  DIGITAL CALIPER
‧Product Info‧
Model/Item No. : H.C.B-A1541
Country of Origin :
Taiwan
Brand :
H.C.B 

Product Specifications /Features : 
* Functions
On/off: Press<on> button once to turn on. Press button an additional time to turn off.
Zero Setting: Press <zero> function button.
Change Measuring Standard: Press<mm/in> function button.
Absolute/Incremental: Press <abs> button, to return to zero function press button again.
* Technical Data
Measuring Range: 0-6”/150mm, 0-8”/200mm,0-12”/300mm
Resolution: 0.0005”/0.01mm
Accuracy: 6”/150mm:±0.001”/±0.02mm
12”/150mm:±0.0015”/±0.04mm
Repeatability: 0.0005”/0.01mm
Measuring system: Capacitive
Display: LCD (10.0 mm high)
Maximum Measuring Speed: 120” per second
Battery: 3V, type CR2032 Lithium
Battery life: Approx. 1 year
Operational Temperature Range: 0℃ to+ 40℃
Maximum Relative Humidity: 80%
Battery Replacement
Once Display beings flashing:
Slide off the battery cover and rubber gasket, and then remove the battery by gently tapping the instrument in your hand. (Never try to face or pry the battery out). Insert the new battery with the positive pole”+” facing upwards and replace the gasket and cover.
Please dispose of used batteries at a proper collection center.
* Cleaning
Clean the caliper with a soft cloth DO NOT use any type of solvent. DO NOT immerse in liquid.
In case of water/coolant splash:
The electronic unit for this instrument is water resistant. In case of liquid splash, the display may possibly fail. Wipe off the liquid, be sure the liquid between the slider and beam is completely dried. Then rest the instrument.
* Troubleshooting Chart
Symtom
Digits do not change or count correctly
No Display
Corrective Action
Remove the battery for 30 seconds then reinstall.
Check battery contacts or replace battery.
RESET: In order to RESET the instrument, remove the battery, wait 30 second, replace the battery and turn the instrument on.
Precautions: Although a top quality product, certain precautions are required for any electronic instrument:
Avoid exposure to all liquids and excessive humidity.
Avoid exposure to electromagnetic fields.
Do not expose the instrument to direct sunlight.
Do not attempt to disassemble the caliper for extended periods of time.  
 
Primary Competitive Advantages :
Well and High Quality Control, Prompt Delivery, Competitive Prices
Sales Method : Export, Manufacture
Payment Term : T/T, L/C at Sight


More info please link: www.hcb-autotools.com

沒有留言:

張貼留言